国语憿情少妇无码av-成人影院yy111111-成人试看120秒体验区-手机黄色小视频-www视频在线观看-毛片视频播放-乱人伦精品视频在线观看-99re久久精品国产首页-中文字幕一区二区三区四区免费看-午夜免费福利-黄色大片一级片-美女久久久久-亚洲毛片精品-就爱操av-国产亚洲精品久久久久久国-日韩中文网-成人免费片

深圳為爾康科技有限公司

檢測認證人脈交流通訊錄

美國RSD RS-240血管造影頭部模體,RS-240血管造影頭模

  • 這真不是您需要的產(chǎn)品?
  • 品  牌:
  • 美國RSD
  • 主要規(guī)格:
  • RSD RS-240血管造影頭部模體,RS-240血管造影頭模
  • 用  途:
  • RSD RS-240血管造影頭部模體,RS-240血管造影頭模
    • 美國RSD RS-240血管造影頭部模體,RS-240血管造影頭模

      型號:RS-240T/RS-240 類別: 質(zhì)控模體 品牌:美國RSD pdf資料: 美國RSD RS-240血管造影頭部模體,RS-240血管造影頭模.pdf

      采購熱線:0755-28896837  13632925349 在線咨詢產(chǎn)品    

      美國RSD RS-240血管造影頭部模體,RS-240血管造影頭模詳細介紹:

      美國RSD RS-240血管造影頭部模體
      三維高對比度血管圖案
      全或半頭
      組織當(dāng)量材料
      階梯楔和分辨率測試模式
      不透明或透明

      美國RSD RS-240血管造影頭部模體填補了物理和解剖信息需求之間的差距。在組織等效材料模型中,精確的男性顱骨包含三維  高對比度血管模擬,以促進放射科醫(yī)師對血管造影圖像質(zhì)量的主觀評估與在相同暴露條件下實際測量分辨率和對比度的相關(guān)性。



      每個RSD RS-240血管造影頭部模體包含一個5步楔形。2-10線對/ mm測試圖案是可選的。其他模式或測試對象和自定義病理可以按照特殊順序提供。

      RSD RS-240血管造影頭部模體提供了一個“空運行”,以完全檢查血管造影設(shè)備,并確保在對患者進行放射性程序之前,在所有重要細節(jié)上都能令人滿意地運行。如果成像系統(tǒng)發(fā)生故障,幻像在隔離和驗證糾正問題方面也起著至關(guān)重要的作用。血管造影頭影像將變量局限于組件和技術(shù),是一種寶貴的服務(wù)和教學(xué)工具。

      獨特的RSD軟組織等效材料被用于皮膚組織和頸部,并被調(diào)整為顱內(nèi)的腦密度。這種材料在放射性吸收和散射特性中密切重復(fù)腦組織。模體幾乎是防碎的。

      高對比度的三維血管圖案被放置在中間平面中。該模式在其早期階段與內(nèi)部頸動脈動脈造影非常相似。血管造影模式的放射密度已被調(diào)整為代表75%的造影劑?;孟罂梢匀轿皇褂?。

      血管造影頭像可以是全頭或半頭。完整的頭部具有代表人體頭部的全散射特性和主體對比度的優(yōu)點。半頭模型非常適合非網(wǎng)格技術(shù)。它具有重量更輕,成本更低,尺寸更小的優(yōu)點,可以輕松裝入公文包中。

      模擬血管圖案,分辨率圖和stepwedge的組合使得用戶能夠?qū)⑽锢韰?shù)(例如分辨率,對比度和速度)與顱骨標記和血管細節(jié)的主觀評估相關(guān)聯(lián)。

      RSD RS-240血管造影頭部模體有透明或不透明的型號。



      ANGIOGRAPHIC HEAD PHANTOMS

      3-dimensional high-contrast vascular pattern
      Full or half-head
      Tissue equivalent materials
      Step wedge and resolution test patterns
      Opaque or transparent
      Alderson ANGIOGRAPHIC HEAD PHANTOMS bridge the gap between physical and anatomical information requirements. Molded in tissue equivalent material, an accurate male skull contains a 3-dimensional,  high-contrast vascular simulation to facilitate correlation of the radiologist's subjective evaluation of angiographic image quality with actual measurements of resolution and contrast under the same exposure conditions.

      Each ANGIOGRAPHIC HEAD PHANTOM contains a 5-step wedge. A 2-10 line pair/mm test pattern is optional. Other patterns or test objects and custom pathologies are available on special order.

      The ANGIOGRAPHIC HEAD PHANTOM provides a "dry run" to completely check out angiographic equipment and ensure that is operating satisfactorily in all significant details before subjecting patients to radiological procedures. If the imaging system malfunctions, the phantom also plays a critically important role in isolating and verifying correction of the problems. The ANGIOGRAPHIC HEAD PHANTOM confines the variables to components and technique and is an invaluable service and teaching tool.

      Unique RSD soft-tissue equivalent material is used for the skin tissue and neck and is adjusted to brain density in the cranium. This material closely duplicates brain tissues in radio-absorptive and scatter properties. The phantom is virtually shatterproof.

      A high contrast 3-dimensional vascular pattern is placed in the median plane. The pattern closely resembles an internal carotid arteriogram in its early phase. The radio-density of the angiographic pattern has been adjusted to represent a 75% contrast-media. The phantom can be used omnidirectionally.

      The ANGIOGRAPHIC HEAD PHANTOM is available as either a full or half head. The full head has the advantage of representing the full scatter properties and subject contrast of a human head. The half-head model is well suited to non-grid techniques. It has the advantages of lighter weight, lower cost and smaller size, easily fitting into a briefcase.

      The combination of the simulated vascular pattern, resolution chart, and stepwedge enables the user to correlate physical parameters (such as resolution, contrast and speed) with the subjective evaluation of the skull markings and the vascular detail.

      The ANGIOGRAPHIC HEAD PHANTOM is available in either transparent or opaque models.

      MODEL NUMBERS
      RS-230
      Opaque Full Angiographic Head with stepwedge
      RS-230T
      Transparent Full Angiographic Head with stepwedge RS-235
      Opaque Full Angiographic Head with resolution test pattern (2-10 1p/mm) and stepwedge
      RS-235T
      Transparent Full Angiographic Head with resolution test pattern (2-10 1p/mm) and stepwedge

      RS-240
      Opaque Half Angiographic Head with stepwedge
      RS-240T
      Transparent Half Angiographic Head with stepwedge
      RS-245
      Opaque Half Angiographic Head with resolution test
      pattern (2-10 1p/mm) and stepwedge
      RS-245T
      Transparent Half Angiographic Head with resolution test pattern (2-10 1p/mm) and stepwedge

      SAG: RSD RS-240,RS-240血管造影頭模,血管造影頭模,RSD RS-240模體,RSD RS-240T模體,RSD模體


      深圳為爾康科技有限公司
      曾生:136-3292-5349  QQ:2747-98107
      電話:0755-28896837
      網(wǎng)址:www-medicalqc-com
      地址:深圳市龍崗區(qū)沙平北路111號吉茂大廈608A

       

       


    • 檢測通手機版

    • 檢測通官方微信

    •  檢測通QQ群
    奈曼旗| 菏泽市| 阳高县| 鹤峰县| 雷波县| 鹿邑县| 潞西市| 晋中市| 通山县| 乾安县| 罗山县| 岗巴县| 呼图壁县| 项城市| 罗甸县| 锡林浩特市| 成安县| 泰来县| 祥云县| 乌鲁木齐市| 文昌市| 四川省| 保康县| 石棉县| 拉孜县| 霍城县| 涟水县| 新田县| 宿松县| 大庆市| 连云港市| 神农架林区| 丰镇市| 兴城市| 江孜县| 革吉县| 岑巩县| 鄂州市| 平湖市| 磐安县| 香港 |